Supporting Exposed Utilities

When you dig up to a gas main, water line or electrical duct, the dirt that held it in place is gone. An unsupported pipe can sag, crack or pull apart at a joint, and a nicked gas line can leak and explode days later.

Photo: exposed gas main supported by straps from a beam spanning the trench, with workers hand-digging around it

Exposing the line

Protect and support

OSHA requires underground installations to be protected, supported or removed as needed while the excavation is open.

Don’t

Report every hit, even a scrape. A dented or scraped gas line, damaged coating, or cut tracer wire must be reported to the utility so they can inspect it. If gas is leaking: stop work, shut off equipment, get everyone away, call 911 and the gas company from a safe distance, and don’t try to stop the leak. See Utility Strikes.

Backfilling around utilities

Use the bedding and backfill material the utility requires, compact in layers, and keep heavy compactors off shallow lines. See Backfilling & Compaction.

Standards & references

Last updated: